WFI systems designs by distillation technologies

Biopuremax Pretreatment – RO membrane – CEDI – Distillation unit
The WFI system design by distillation method is based on the following Water for Injection equipment MMF (Multimedia filter)

  1. City water tank
  2. Cooling/heating Heat exchanger
  3. Optional Electrical heating elements if steam is not available.
  4. City water circulation pump – SS 316, resistant to Hot Water Sanitization
  5. ESR™ – reactors fully fabricated from SS316L
  6. SS 316 filter – one unit of 10 micron
  7. SS 316 filter – one unit of 3 micron
  8. HOD™ – UV lamp to reduce free chlorine from max 0.5 ppm to 0.05 ppm
  9. Hot water sanitized (HWS) single pass RO
  10. Hot water sanitized CEDI